« Back to Product

Documentation

Eltako BR14

Require: Symcon >= 7.1

The devices of the Eltako series 14 (BR14) are DIN rail devices for the control cabinet which are connected with each other via the Eltako Bus14. Symcon is connected via the Eltako FGW14 to the RS232 interface of the SymBox and communicates with the devices via the EnOcean Gateway. With the module "PCT14 Importer" the devices can be created in Symcon directly from a PCT14 export.

Warning

The general integration of EnOcean devices is described at EnOcean.

Requirements

  • Symcon version 7.1 or later
  • Eltako FAM14 and Eltako FGW14 per Bus14 line
  • SymBox with integrated RS232 extension (or another RS232 interface)
  • Eltako PCT14 software for configuring the devices

Installation

The Eltako FGW14 is connected to a SymBox via RS232. The SymBox must have the RS232 module fitted. The FGW14 is in turn connected to the Eltako FAM14 via the "Eltako Bus14" pluggable jumper bridges. The following connectivity configuration is to be observed:

FAM14:

  • Rotary Mode Selector (BA):
    Set According to manual. Select mode 2 for bi-directional communication.
    Select mode 1 for address assignment.

  • Terminal Pins "N" and "L":
    Connect with 230V mains power. Either by attaching a suitable mains plug or connect directly to live and neutral rail inside a control cabinet or fuse box.

  • Terminal Pin "Hold":
    Connect with terminal pin "Hold" on FGW14.

  • Terminal Pin "GND":
    Connect with ground pin (⊖) of the RS232 interface of the SymBox.

FGW14:

  • Rotary Mode Selector (BA):
    Select mode 6: "Bus14 ↔ RS232 58k Baud".

  • Terminal Pin "Hold":
    Connect with terminal pin "Hold" on FAM14.

  • Terminal Pin "Tx":
    Connect with terminal pin ↓ of the RS232 interface of the SymBox.

  • Terminal Pin "Rx":
    Connect with terminal pin ↑ of the RS232 interface of the SymBox.

For importing the devices, the module "PCT14 Importer" is additionally installed via the Module Store. The source code is available on GitHub.

Integration in Symcon

The data flow consists of a Serial Port (I/O), an EnOcean Gateway (splitter) and the EnOcean device instances. A separate EnOcean Gateway with its own Serial Port is created for each Bus14 line. The devices can either be imported with the PCT14 Configurator or created manually.

Gateway

Via "Add Instance" an "EnOcean Gateway" is created and connected to the Serial Port the FGW14 is attached to. The setting of Baud rate etc. is not required and is done automatically by the system.

Name Description
Gateway Mode Mode for the Eltako FGW14
BaseID BaseID of the Bus14 line (FAM14). The BaseID can be viewed in PCT14
Warning

How the I/O instance (parent instance of the gateway) is selected and eventually replaced, can be found here: Replace I/O Instance

PCT14 Configurator

The PCT14 Configurator reads the XML file exported from PCT14 and lists all devices and channels of the line. Supported devices can be created as instance directly.

  • Via "Add Instance" the module "PCT14 Configurator" can be found using the quick filter.
  • Further information about adding instances can be found in the documentation of the instances
  • The EnOcean Gateway of the desired line is selected as parent instance. The BaseID is taken automatically from this gateway and newly created devices are connected to this gateway.
  • For multiple lines, a separate PCT14 Configurator is created for each line.
Warning

If no EnOcean Gateway is connected or the gateway has no valid BaseID, the configurator shows a hint and does not list any devices from the XML file.

For each device, the configurator checks whether a matching entry for Symcon with the BaseID of the line exists in the "ID allocation area" of PCT14. If the entry is missing or does not match, it is added or corrected in the XML file and the device is marked as "Needs updating". In this case, the following procedure is carried out:

  1. Download the adjusted XML file in the dialog.
  2. Import the XML file into PCT14 and program the affected devices.
  3. Export the new XML file from PCT14 and select it again in the PCT14 Configurator.

Configuration page (PCT14 Configurator)

Name Description
PCT14 XML Export The XML file exported from PCT14

The column "Status" of the device list shows the following values:

Status Description
OK (ID) The device is configured correctly and can be created. The ID is the Device ID in Symcon
Needs updating The XML file was adjusted. The device must be programmed again via PCT14
Slots are full There is no free slot left in the "ID allocation area" of the device
Unsupported device The device is not supported by the PCT14 Configurator
OK (Not required) The device does not require its own instance (e.g. FGW14)

The following devices are supported by the PCT14 Configurator:

Device Function
FSR14-2x, FSR14-4x Switch actuator
F4SR14-LED Switch actuator
FUD14, FUD14/800W Dimming actuator
FSB14 Shutter actuator
FHK14, F4HK14 Heating/cooling relay
FWG14MS Weather station

Manual setup

Alternatively, the devices can also be created manually via an EnOcean Configurator or "Add Instance":

  • Assign an ID to the devices via login at the FAM14 (see manufacturer manual)
  • Enter Device ID and confirm with "Apply"
  • It can be seen easiest via the PCT14
  • Put device into teach in mode (see manufacturer manual)
  • Click "Teach In" in the Symcon instance
  • Eventually test functionality with On/Off in the test environment
  • Click "Search". The device should switch On/Off five times
  • Select found ID and confirm with "OK"

Special handling for certain devices

  • FUD14: In PCT14, in the configuration area, the options "Confirmation Telegram with Dim Value" and "Confirmation Telegram with Button Telegram" must be set to "On". If not inserted by the teach in, the function 32 "Dim Value from GFVS / Rotary Switch" must be configured in function group 3 of the tab "ID - Allocation Area" of the device.
  • FSR14-xR: Must be teached in as directional button or universal button, depending on whether the button should switch On/Off or switch with two buttons.
  • FSB14: If not inserted by the teach in, the function "Drive Time with predefined time value FVS" must be configured in the function group of the tab "ID - Allocation Area" of the device in PCT14.
Warning

For Eltako devices, the switch actor must be taught in in directional button mode. The dim actor must be taught in in the mode P,L,C (also PCT). This is realized by the especially available instance and the Teach In button. (since IP-Symcon 2.5)

Warning

The device Eltako FSB14 can only be taught in in RV 180/200 (Motor 1/2).

ID Description
Device ID Provided by the user. 0-127 in whole numbers possible
Report ID Sent by the device. Used for device allocation

Troubleshooting

Warning

While the connection between FAM14 and PCT14 is active via USB, wireless telegrams cannot be sent.

Any questions?