Documentation
Devices
1-Wire
Functions for accessing 1-Wire components
DS2405 | 1-fach Switch | ||||||||||
| |||||||||||
DS2406 | 2-fach Switch | ||||||||||
| |||||||||||
DS2408 | 8-fach Switch | ||||||||||
| |||||||||||
DS2413 | 2-fach Switch | ||||||||||
| |||||||||||
DS2438 | Smart Battery Monitor | ||||||||||
DS2450 | A/D-Wandler 16bit | ||||||||||
| |||||||||||
DS2890 | Digital-Potentiometer 8 bit | ||||||||||
| |||||||||||
Device List | Device list 1-Wire | ||||||||||
OW_RequestStatus | Executes a new read for the device with the ID __InstanceID__. |
ABL
Setup of ABL devices
Device-List |
Alfen
Alfen device setup
Device List |
ALLNET
Funktionen zur Ansteuerung von ALLNET Komponenten
ALL_SetAnalog | sets the analog value of a channel |
ALL_SwitchActor | switches an ALLNET actuator on/off |
ALL_SwitchMode | Switches the device with the ID __InstanceID__ to value __Status___ |
ALL_UpdateValues | Executes a update of the state variables for the device with the ID __InstanceID__. |
Device list | Device list ALLNET |
BACnet
Functions for controlling BACnet components
BAC_RelinquishPresetValue | Resetting the preset value |
digitalSTROM
Functions for controlling digitalSTROM components
DS_CallScene | calls up a scene |
DS_DimSet | dims a digitalSTROM terminal to a specific value |
DS_MakeRequest | sends a digitalSTROM command directly to the dSS |
DS_RequestStatus | retrieves the status |
DS_ShutterMove | moves the roller shutter to a desired position/stop |
DS_ShutterMoveDown | moves the roller shutter down to the end position/stop |
DS_ShutterMoveUp | moves the roller shutter up to the end position/stop |
DS_ShutterStop | stops a motion |
DS_SwitchMode | switches a digitalSTROM terminal on/off |
Device list | DigitalSTROM device list |
DMX / ArtNet
Functions for controlling DMX components
DMX_FadeChannel | Dims the __Channel__ of the device with ID __InstanceID to __Value__ with a certain __FadeTime__ |
DMX_FadeChannelDelayed | Dims the __Channel__ of the device with ID __InstanceID to __Value__ with a certain __FadeTime__. You can specify a __DelayTime__ after which the dimming starts. |
DMX_FadeRGB | dims the RGB channel with a fade time |
DMX_FadeRGBDelayed | dims the RGB channel with a fade time |
DMX_RequestInfo | Queries the information of a DMX instance |
DMX_ResetInterface | Sets the DMX interface back with the ID __InstanceID__. It is recommended that in case of problems, create a script with this command and declare it as startup script. - |
DMX_SetBlackout | Sets all channels of DMX interfaces with ID __InstanceID__ to value __ Status__. |
DMX_SetChannel | Switches the channel from the device with the ID __InstanceID__ to value __Wert__ |
DMX_SetRGB | sets the RGB channel to a certain value |
Device list | Device list DMX |
EgiGeoZone
Receives data from the EgiGeoZone app for Google Android.
ekey
Functions for controlling ekey components
Device list | Device list eKey |
ekey bionyx
EnOcean
Functions for accessing EnOcean components
ENO_DimSet | Dims the device with ID __InstanceID__ to value __Intensity__. |
ENO_SetActiveMessage | activates a certain message |
ENO_SetFanStage | sets the FanStage to a certain value |
ENO_SetIntensity | Dims the device with ID __InstanceID__ to value __Intensity__. The value __Status__ indicates whether the device is to be switched on/ off. |
ENO_SetLockFanStage | locks the FanStage |
ENO_SetLockRoomOccupancy | locks the occupancy |
ENO_SetMode | sets the actuator in a certain mode |
ENO_SetPosition | sets the position of the actuator |
ENO_SetRoomOccupancy | sets the occupancy to true/false |
ENO_SetTemperature | sets the actuator to a certain target temperature |
ENO_SetTemperature1 | sets the device to a certain temperature |
ENO_ShutterMoveDown | moves the roller shutter down to the end position/stop |
ENO_ShutterMoveDownEx | moves the roller shutter for a certain time |
ENO_ShutterMoveUp | moves the roller shutter up to the end position/stop |
ENO_ShutterMoveUpEx | moves the roller shutter for a certain time |
ENO_ShutterStop | stops a motion |
ENO_SwitchMode | Switches the device with ID __InstanceID__ to value __Status__ |
ENO_SwitchModeEx | Switches the device with ID __InstanceID__ to value __Status__ |
Device list | Device list EnOcean/EEP |
FHZ1X00PC
Funktionen zur Ansteuerung von FS20, HMS, FHT Komponenten
FHT | Funk-Heizungssystem | ||||||||||
| |||||||||||
FS20 | FunkSystem für digitale Geräte | ||||||||||
| |||||||||||
Device list | Device list FHZ | ||||||||||
HMS | HouseMessageSystem for analogue devices | ||||||||||
| |||||||||||
KS300 | Kombisensor Wetterstation |
FS10 Weather
Wetterstation mit Funk auf 433MHz
GARDENA smart system
Module for adding GARDENA smart system devices
smart Irrigation Control | A GARDENA irrigation control with 6 valves |
smart SILENO Mower | A smart SILENO Mower from GARDENA |
smart Power Socket | A power socket from GARDENA |
smart Pressure Pump | A GARDENA smart Pump with one valve |
smart Sensor | A GARDENA smart sensor with various measured values |
smart Water Control | A GARDENA Irrigation Control with one valve |
Geofency
Receives data from the Geofency app for Apple iOS.
Heating Control
Funktionen zur Ansteuerung vom Heizungsmodul zur Regelung von Raumtemperaturen
HC_TargetValue | Sends via the instance with the ID __ InstanceID__ a target value to the heating module. |
Home Connect
Module for adding Home Connect devices
Device list | Device list Home Connect |
Home Connect Device | The device instance created by the Home Connect configurator |
HomeMatic
Device list | HomeMatic Device List | ||||||||||||||
HomeMatic CCU | Functions for controlling HomeMatic components | ||||||||||||||
| |||||||||||||||
HomeMatic HCU (Beta) |
Image Grabber
Module for querying webcam images
IG_UpdateImage | updates the image of the instance |
IPS-868
Functions for controlling IPS868 components
AKM-868 | Anwesenheitskontrollmodul mitsamt Tracker | ||||||||||
ANA-868 | Analog-to-digital converter | ||||||||||
| |||||||||||
EKM-868 | Ein Energiekontrollmodul mit 4-Kanal-Zählermodul mit je 32 Bit | ||||||||||
| |||||||||||
FD-868 | Ein Funkdisplay mit einem 2*16-stelligen LC-Display | ||||||||||
| |||||||||||
Device list | Device list IPS 868 | ||||||||||
JKM-868 LevelJET | A reader for LevelJET level indicator | ||||||||||
| |||||||||||
JKM-868 ThermoJET | A reader for individual values of the ThermoJET temperature controller | ||||||||||
| |||||||||||
LGS-868 | Air quality sensor for room air analysis | ||||||||||
| |||||||||||
RGBW-868 | Steuergerät für LED-RGBW-Stripes | ||||||||||
| |||||||||||
SERVO-868 | A 4-way servo control module | ||||||||||
| |||||||||||
WDT-868 | Ein Watch-Dog-Timer zur Überwachung des Systems | ||||||||||
|
IR Trans
Funktionen zur Ansteuerung von Infrarot Komponenten
Device list | Device list IR-Trans |
IRT_SendOnce | sendet einen IR Befehl |
KEBA
Device List |
KNX
Functions for controlling KNX components
EIB_Char | Sends a single letter |
EIB_Counter8Bit | sends an 8-bit counter value |
EIB_Counter16Bit | sends a 16bit counter value |
EIB_Counter32bit | sends a 32bit counter value |
EIB_Date | sends the date value |
EIB_DimControl | Sends a dim value date __Value__ to the device with the ID __InstanceID__. Depending on the configuration 0..15 (Standard) or -7..7 (Enhanced) can be sent. |
EIB_DimValue | Sends the dim value __Value__ to the device with the ID __InstanceID__. Depending on configuration 0..255 (Standard) or 0..100 (Percent) will be passed as the value parameter. |
EIB_DriveBladeValue | Sends the position value __Value__ to the device with the ID __InstanceID__. Depending on configuration 0..255 (Standard) or 0..100 (Percent) will be passed as the value parameter. |
EIB_DriveMove | Moving the device with ID __InstanceID__ in a particular __Direction__. Depending on configuration the movement direction can be inverted. - |
EIB_DriveShutterValue | Sends the position value __Vert__ to the device with the ID __InstanceID__. Depending on configuration 0..255 (Standard) or 0..100 (Percent) will be passed as the value parameter. |
EIB_DriveStep | Moving the device __Stepwise__ with ID __InstanceID__ into a determined __Direction__. Depending on the configuration, the movement direction can be inverted. |
EIB_FloatValue | sends a float value |
EIB_Move | moves a roller shutter |
EIB_Position | moves a roller shutter to a position |
EIB_PriorityControl | sets a device state |
EIB_PriorityPosition | Sets the device with ID __InstanceID__ to a certain __Direction__. Depending on configuration the direction can be inverted. |
EIB_RequestStatus | sends a read request for EIB instances to the bus |
EIB_Scale | Sends the Value __Value__ to the device with the ID __InstanceID__. Depending on configuration 0..255 (Standard) or 0..100 (Percent) will be passed as the value parameter. |
EIB_SetRGB | sets an RGB stripe to a specific color |
EIB_SetRGBW | sets an RGBW stripe to a specific color |
EIB_Str | sends a text |
EIB_Switch | Switches the device with the ID __InstanceID__ to value __Status__ |
EIB_Time | sends a time value |
EIB_Value | Sends the value __Value__ to the device with ID __InstanceID__. |
Device list | Device list EIB/KNX |
KNX_RequestStatus | sends a read request for DPT instances on the bus |
LCN
Functions for controlling LCN components
Device list | Device list LCN |
LCN_AddGroup | adds a device to a group |
LCN_AddIntensity | Dims the device with ID __InstanceID__ brighter by the value __Intensity__. |
LCN_AddThresholdCurrent | adds threshold to current value |
LCN_AddThresholdDefined | adds threshold to predefined value |
LCN_Beep | Lets the instance with the ID __InstanceID__ beep |
LCN_DeductIntensity | Dims the device with ID __InstanceID__ darker by the value __Intensity__. |
LCN_DeductThresholdCurrent | deducts threshold from current value |
LCN_DeductThresholdDefined | deducts threshold from predefined value |
LCN_FadeOut | Dims the devive with ID __InstanceID__ to value __Intensity__ and dims then with the __Ramp__ seconds down to 0%. |
LCN_FlipRelay | Switches over the relay with the ID __InstanceID__ |
LCN_LimitOutput | limits an output for a certain period of time |
LCN_LoadScene | calls up a scene for an output |
LCN_LockTargetValue | locks a controller of the device |
LCN_RampStop | Stops the dimming process of the device with the ID __InstanceID__ |
LCN_ReleaseTargetValue | unlocks a controller of the device |
LCN_RemoveGroup | removes a device from a group |
LCN_RequestLights | queries the LEDs of the panel |
LCN_RequestRead | queries the values |
LCN_RequestStatus | queries all statuses of the module |
LCN_RequestThresholds | queries thresholds and hysteresis |
LCN_SaveScene | saves a scene for an output |
LCN_SelectSceneRegister | selects a register |
LCN_SendCommand | Sends a custom command to the instance with the ID __InstanceID__. For possible commands, refer to the PCHK documentation. If you do not have this, you can possibly refer to your dealer. We do not provide this option. |
LCN_SetDisplayText | Shows a text on a line of the display |
LCN_SetDisplayTime | sets the display time of a line in the display |
LCN_SetIntensity | Dims the device with the ID __InstanceID__ to value __Intensity__ in __Ramp__ seconds. |
LCN_SetLamp | switching an LED |
LCN_SetRelay | setzt alle Relais in einem Modul (8Bit) |
LCN_SetRGBW | sets an instance to an RGBW color value |
LCN_SetTargetValue | Sets the regulator __Target__ of the instance with the ID __InstanceID__ to the value __Value__ |
LCN_ShiftTargetValue | Shifts the current target value |
LCN_ShutterMove | starts shutter movement to percentage position |
LCN_ShutterMoveDown | starts a shutter movement downwards |
LCN_ShutterMoveUp | starts a shutter movement upwards |
LCN_ShutterStop | stops a shutter movement |
LCN_StartFlicker | Let the device with the ID __InstanceID__ flicker |
LCN_StopFlicker | Stop flickering of the device with the ID __InstanceID__ immediately |
LCN_SwitchDurationMin | after how many minutes it should be dimmed down |
LCN_SwitchDurationSec | after how many seconds it should be dimmed down |
LCN_SwitchMemory | Switches the device with the ID __InstanceID__to a stored value |
LCN_SwitchMode | schaltet ein Gerät an/aus |
LCN_SwitchRelay | Switches the relay with the ID __InstanceID__ to value __Status__ |
LCN_SwitchRelayTimer | switches a relay on a time factor |
LJQuick
The KNX quick (Lingg&Janke) module supports the setup of KNX instances.
LJ_SendDateTime | Sends the current date/time to the KNX bus |
M-Bus
Functions for controlling M-Bus components
Device list | Device list M-Bus |
MBUS_UpdateValues | updates all device-specific values |
Mennekes
Mennekes device setup
Device List |
Modbus RTU/TCP
Functions for controlling ModBus RTU/TCP components
Device list | Device list ModBus RTU/TCP |
ModBus_RequestRead | Executes a new read for the device with the ID __InstanceID__. |
ModBus_WriteCoil | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegister | writes a value to the write address |
ModBus_WriteRegisterByte | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterChar | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterDWord | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterInt64 | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterInteger | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterReal | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterReal64 | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterShort | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterString | Sets address with ID __InstanceID__ to __Value__ |
ModBus_WriteRegisterWord | Sets address with ID __InstanceID__ to __Value__ |
Möhlenhoff Alpha 2
Receiving and switching Möhlenhoff Alpha2 data
MA2_RequestStatus | Gets the values stored in the Alpha2 with the InstanceID and sets the associated variables. |
MA2_WriteValue | Writes the Value into the variable with the Ident in the Möhlenhoff Alpha 2 with the InstanceID. |
MQTT
Functions for controlling MQTT components
Device list | Device list MQTT |
MQTT Client | Functions for controlling MQTT Client |
MQTT-Server | Functions for controlling MQTT Server |
NEA Smart
Receiving and switching NEA Smart data
NEAS_RequestStatus | Gets the values stored in the NEA Smart with the InstanceID and sets the associated variables. |
NEAS_WriteValue | Writes the Value to the variable with the ident in the NEA Smart with the InstanceID. |
OCPP
Über das OCPP Protokoll können Wallboxen bequem über Symcon überwacht und geschaltet werden.
OCPP_RemoteStartTransaction | If the status is 'Preparing' or 'Finishing', loading can be enabled by this command. |
OCPP_RemoteStopCurrentTransaction | If the state is 'Charging', this command can be used to stop charging. |
OCPP_RemoteStopTransaction | If the state is 'Charging', this command can be used to stop charging. |
OPC UA
Functions for controlling OPC UA components
SageGlass (BACnet)
Integrates the SageGlass SIM II (BACnet) with IP-Symcon
Shutter Control
Functions for controlling shutter (roller shutter) components
SC_Move | bewegt den Rollladen an eine bestimmte Position |
SC_MoveDown | bewegt den Rollladen bis zu Endposition runter |
SC_MoveUp | bewegt den Rollladen bis zu Endposition hoch |
SC_Stop | stoppt einen Bewegungsvorgang |
Siemens OZW
Funktionen zur Ansteuerung von Siemens OZW Komponenten
Device list | Device list Siemens OZW |
OZW_RequestStatus | requests the status of a device |
OZW_WriteDataPoint | writes a specific value to a data point |
SNMP
Show values for any OIDs of a walk. Optionally, these can be created and described as variables.
SNMP_UpdateValues | Updates the variable values which are below the instance. |
Snom
Integration of Snom IP phones
PLC: Siemens, Vipa, Logo
Functions for controlling Siemens/Vipa/Logo PLC components
Device list | Device list SPS Siemens/Vipa |
Logo-VM-Addresses | VM addresses of Logo7/8 |
S7_RequestRead | performs a read operation on a device |
S7_Write | writes a value to the configured address |
S7_WriteBit | Set the address with the ID __InstanceID__ to value status |
S7_WriteByte | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteChar | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteDWord | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteInteger | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteReal | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteShort | Set the address with the ID __InstanceID__ to __Value__ |
S7_WriteWord | Set the address with the ID __InstanceID__ to __Value__ |
PLC: Wago, Beckhoff, ABB
Functions for controlling Wago/Beckhoff PLC components
Sync Remote
Synchronization between two Symcon systems
Technische Alternative
Functions for controlling Technische Alternative components
Device list | Device list Technische Alternative |
Voice over IP
Functions for controlling VoIP
Device list | Device list Voice over IP |
VoIP_AcceptCall | accepts a connection |
VoIP_Connect | establishes a connection |
VoIP_Disconnect | terminates a connection |
VoIP_GetConnection | returns information about a connection |
VoIP_GetData | returns data of a connection |
VoIP_PlayWave | plays a wave file |
VoIP_RejectCall | rejects a connection |
VoIP_SendDTMF | sends a sequence of characters as DTMF |
VoIP_SetData | sets the data of a connection |
WinLIRC
Funktionen zum Ansteuern von WinLIRC Komponenten
WinLIRC_SendOnce | Sends a remote command on the instance with ID __InstanceID__. The values remote control and button specify, which command should be sent. These must be set up accordingly in the client software (WinLIRC/ IRTrans Tray). |
Wireless M-Bus
Functions for controlling wireless M-Bus components
Device list | Wireless M-Bus device list |
WMRS200
Functions for controlling WMRS200 components
Device list | Device list WMRS200 |
W&T
Functions for controlling W&T components
WUT_SwitchMode | Switches the channel with ID __InstanceID__ to value __Status__. |
XBee
Functions for controlling XBee
XBee_SendBuffer | sends a data string to a specific device |
XBee_SendCommand | sends a command to a specific XBee-Splitter |
Eaton xComfort
Funktionen zur Ansteuerung von xComfort Komponenten
Device list | Device list Eaton xComfort |
MXC_DimBrighter | fängt einen Dimmvorgang auf eine hellere Stufe an |
MXC_DimDarker | fängt einen Dimmvorgang auf eine dunklere Stufe an |
MXC_DimSet | dimmt ein xComfort Gerät auf eine bestimmte Stufe |
MXC_DimStop | hält einen Dimmvorgang an |
MXC_RequestStatus | sende eine Statusmeldungsanfrage an ein Gerät |
MXC_SendBoolean | Sends a boolean value to the instance with ID __InstanceID__, which is connected to a room manager. |
MXC_SendFloat | Sends a float to the instance with ID __InstanceID__, which is connected to a room manager. |
MXC_SendInteger | Sends a boolean value to the instance with ID __InstanceID__, which is connected to a room manager. |
MXC_SetTemperature | Sets the new target temperature of the control valve with the ID __InstanceID__ to the new __Temperature__. |
MXC_ShutterMoveDown | bewegt den Rollladen nach unten bis zur Endposition/Stop |
MXC_ShutterMoveUp | bewegt den Rollladen nach oben bis zur Endposition/Stop |
MXC_ShutterStepDown | bewegt den Rollladen ein Stück nach unten |
MXC_ShutterStepUp | bewegt den Rollladen ein Stück nach oben |
MXC_ShutterStop | stoppt einen Bewegungsvorgang |
MXC_SwitchMode | schaltet ein xComfort Gerät an/aus |
Z-Wave
Functions for controlling Z-Wave components
Device list | Device list Z-Wave |
ZW_Basic | Turns the basic function of the specified device with InstanceID __InstanceID__ |
ZW_ColorCW | sets the cold-white channel of a RGBWW Z-Wave device |
ZW_ColorRGB | sets the color of a Z-Wave device |
ZW_ColorRGBWW | sets the colors and intensity of an RGBWW Z-Wave device |
ZW_ColorWW | sets the WarmWhite channel of a Z-Wave device |
ZW_DimDown | starts dimming down |
ZW_DimDownEx | starts dimming down with a runtime |
ZW_DimSet | dimmt ein Z-Wave Gerät auf eine bestimmte Stufe |
ZW_DimSetEx | dims a Z-Wave device to a specific level within a runtime |
ZW_DimStop | stops dimming a Z-Wave device |
ZW_DimUp | starts dimming up |
ZW_DimUpEx | starts dimming up within a runtime |
ZW_DoorLockOperation | Sets the door lock operation mode of a Z-Wave device |
ZW_LockMode | sets the LockMode |
ZW_MeterReset | resets the meter |
ZW_Optimize | Starts the wireless network optimization process for a Z-Wave device |
ZW_ProtectionSet | sets the Protection and its Mode |
ZW_RequestStatus | Queries the status from the device with the ID __InstanceID__. Only power-operated devices can be queried directly by command, because battery-operated devices do not permanently listen to the queries. |
ZW_ShutterMoveDown | Moves the shutter with the ID __InstanceID__ downwards until (link: page://f1hDSVmdoBuVvjEW text: MXC_ShutterStop) is running or the end position is reached. |
ZW_ShutterMoveUp | Moves the shutter with the ID __InstanceID__ upwards until (link: page://f1hDSVmdoBuVvjEW text: MXC_ShutterStop) is running or the end position is reached. |
ZW_ShutterStop | Stops a current movement of the shutter. |
ZW_SwitchAllMode | Sets the Switch All mode of a Z-Wave device |
ZW_SwitchMode | schaltet ein Z-Wave Gerät an/aus |
ZW_Test | Tests if a connection to a Z-Wave device is working |
ZW_ThermostatFanModeSet | Sets the FanMode for the thermostat |
ZW_ThermostatModeSet | Sets the thermostat mode |
ZW_ThermostatSetPointSet | Sets the PointSet Value |
Zevvy
Sends data to a Zevvy account
ZY_SendMeasurements | Sends the data of the set up variables to a Zevvy account |